From: route@monster.com
Sent: Thursday, September 10, 2015 3:45 PM
To: hg@apeironinc.com
Subject: Please review this candidate for: osp
This resume has been forwarded to
you at the request of Monster User xapeix03
|
|||||||
|
|||||||
|
|
|
||||||
|
||||||
|
Richard Lee Johnson 110 Brentwood ct Mooresville NC 28115® C) 704-351-0846 Email: reddhott8058@yahoo.com CATV NETWORK TECHNICIAN with 24 years of experience from entry level
Installer to Network Maintenance Tech III, to Head End and OSP construction,
fiber optics including FTTH; and background in all scopes of wiring for CATV,
HSD, VoIP from drop plant to HFC distribution to the Head End / Hub wiring EDUCATION and TRAINING Richlands High School Richlands ,VA- General Studies (1984-1988) ® NCTI courses ® Installer ® Service Tech I, II ® System Tech I, II ® Advanced Systems Tech I ® NCTI Installer ® First Aid/CPR Certification-MI-CONNECTION ® Confined Space Entry Certification ® Aerial Lift Operation Certification Adelphia Cable ® TE certification for installation, maintenance & troubleshooting
Prism & Spectrum ® Class A CDL w/ valid medical card ® Fiber Tech WORK EXPERIENCE MI-Connection 2009– Present NETWORK MAINTENANCE TECHNICIAN III Conducted outside plant maintenance and repairs, using a 45ft lift
truck, 28ft extension ladder and gaffs as necessary, wiring hub sites for
expansion and upgrade of existing equipment( Electroline FCD/RCD units, S/A
Hydrox Optical Receivers, Phillips Receivers, Motorola GX2 forward
transmitters, Antec Laser Link and Laser Link II transmitters CCOR
transmitters & receivers, Trilithic return sweep / Ingress gear,
fusion splicing fiber/ troubleshooting fiber optics (Mux DeMux,single mode,
ribbon/ loose tube), splicing coaxial cables (PIII, MC2,RG59,6, and 11); also hardline coax, CAT5
wire. Worked closely with vendors ( ALPHA, MOTOROLA,SA-CISCO,
ARRIS-CCOR, MAGNAVOX) to ensure proper installation of various products
related to RF, VoIP, HSD services. Ensured proper set up of the network
amplifiers. Worked with EDSM status monitored power supplies and other
routine power supply maintenance. Conducted FCC required POP testing (24hr
& distortion testing).Also worked a On-Call Rotation with other maint techs.
Also experienced in Aerial Mainline construction and underground splicing and
activation with system design and prints HEADEND TECHNICIAN-Adelphia Cable/Time Warner Cable-2003-2008 Conducted inside, wiring hub sites and headends for expansion and upgrade
of existing equipment( Electroline FCD/RCD units, S/A Hydrox Optical
Receivers, Phillips Receivers, Motorola GX2 forward transmitters, Antec Laser
Link and Laser Link II transmitters CCOR transmitters & receivers,
Trilithic return sweep / Ingress gear, fusion splicing fiber/
troubleshooting fiber optics (Mux DeMux,single mode, ribbon/ loose tube),
splicing coaxial cables (PIII, MC2,RG59,6, and 11); also hardline coax, CAT5
wire. Worked closely vendors ( ALPHA, MOTOROLA, ARRIS-CCOR, MAGNAVOX)
to ensure proper installation of various products related to RF, VoIP, HSD
services. Ensured proper set up of the network amplifiers. Worked with
EDSM status monitored power supplies worked with keep Catv channels up and
working adjusted levels .Worked with G-Quams and quam modulaters and forward
and return combing and assited maintenance tech in trouble shooting Return
Noise problems and optimizing nodes to Spec,, Underground Locater/SERVICE TECHNICIAN/Maintenance Tech
(Prestige Cable/Adelphia Cable) – 1995-2003 Ensured the wiring scope within the customer’s home was to company
requirements, handled customer complaints and took necessary steps to resolve
issues.Also worked with Settop boxes cable modems MTA and ONT .Also worked on
fiber to the home projects. INSTALLER (Adelphia Cable) – 1990-1993 Wired customer homes to satisfy work order and ensure that services
being ordered by the customer were working properly. TOOLS / EQUIPMENT Extensive working knowledge of cable industry installation /
troubleshooting tools and test equipment as follows: ® Spectrum Analyzers -Agilent, HP 9581C, Sunrise Telecom AT2500QR ® Fujikura Fusion Splicer ® Noyles OTDR ® CableScout and Riserbond TDR ® Volt/Ohm Meters ® SLM- Acterna SDA5000 Trilithic RSVP2, SSR, & 860DSPi (also
associated hub equipment SST9580 & TPX) COMPUTER SKILLS Microsoft Office Suite 2000 and 2003 REFERENCES- KEVIN JOYCE-704-351-7137-CONSTRUCTION SUPERVISIOR GARY SMITH-704--351-5210-FIBER SPLICER TODD HEYWORTH-704-677-3827-FORMER SUPERVISIOR |
|
|
||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|